diff --git a/config/interface/input_elements/demand_households_heating.yml b/config/interface/input_elements/demand_households_heating.yml index 11adda8fb..5484ce4ce 100644 --- a/config/interface/input_elements/demand_households_heating.yml +++ b/config/interface/input_elements/demand_households_heating.yml @@ -84,7 +84,7 @@ related_node: households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity position: 105 dependent_on: has_coal_oil_for_heating_built_environment - slide_key: demand_households_heating + slide_key: demand_households_heating - key: households_heater_heatpump_pvt_electricity_share share_group: heating_households step_value: 0.1 @@ -135,6 +135,22 @@ position: 170 dependent_on: has_coal_oil_for_heating_built_environment slide_key: demand_households_heating +- key: households_heater_hybrid_airconditioning_combined_network_gas_share + share_group: heating_households + step_value: 0.1 + unit: "%" + interface_group: space_and_water_heating_technologies + related_node: households_space_heater_hybrid_airconditioning_combined_network_gas + position: 180 + slide_key: demand_households_heating +- key: households_heater_airconditioning_with_heat_pump_boiler_share + share_group: heating_households + step_value: 0.1 + unit: "%" + interface_group: space_and_water_heating_technologies + related_node: households_space_heater_airconditioning_with_heat_pump_boiler + position: 190 + slide_key: demand_households_heating - key: households_water_heater_solar_thermal_share step_value: 0.1 diff --git a/config/interface/input_elements/demand_households_heating_technologies.yml b/config/interface/input_elements/demand_households_heating_technologies.yml index fa5df2fcf..138940d2b 100644 --- a/config/interface/input_elements/demand_households_heating_technologies.yml +++ b/config/interface/input_elements/demand_households_heating_technologies.yml @@ -1,11 +1,27 @@ --- +- key: households_heater_coal_heat_output_capacity + step_value: 0.1 + unit: "kW" + interface_group: capacity + related_node: households_space_heater_coal + position: 5 + dependent_on: has_coal_oil_for_heating_built_environment + slide_key: demand_households_heating_technologies +- key: households_heater_crude_oil_heat_output_capacity + step_value: 0.1 + unit: "kW" + interface_group: capacity + related_node: households_space_heater_crude_oil + position: 10 + dependent_on: has_coal_oil_for_heating_built_environment + slide_key: demand_households_heating_technologies - key: households_heater_network_gas_heat_output_capacity step_value: 0.1 unit: "kW" interface_group: capacity related_node: households_space_heater_network_gas position: 15 - slide_key: demand_households_heating_technologies + slide_key: demand_households_heating_technologies - key: households_heater_combined_network_gas_heat_output_capacity step_value: 0.1 unit: "kW" @@ -96,7 +112,7 @@ interface_group: capacity related_node: households_space_heater_hybrid_hydrogen_heatpump_air_water_electricity position: 80 - slide_key: demand_households_heating_technologies + slide_key: demand_households_heating_technologies - key: households_heater_hybrid_crude_oil_heatpump_air_water_electricity_heat_output_capacity step_value: 0.1 unit: "kW" @@ -104,20 +120,18 @@ related_node: households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity position: 85 dependent_on: has_coal_oil_for_heating_built_environment - slide_key: demand_households_heating_technologies -- key: households_heater_coal_heat_output_capacity + slide_key: demand_households_heating_technologies +- key: households_heater_airconditioning_with_heat_pump_boiler_heat_output_capacity step_value: 0.1 unit: "kW" interface_group: capacity - related_node: households_space_heater_coal - position: 5 - dependent_on: has_coal_oil_for_heating_built_environment + related_node: households_space_heater_airconditioning_with_heat_pump_boiler + position: 90 slide_key: demand_households_heating_technologies -- key: households_heater_crude_oil_heat_output_capacity +- key: households_heater_hybrid_airconditioning_combined_network_gas_heat_output_capacity step_value: 0.1 unit: "kW" interface_group: capacity - related_node: households_space_heater_crude_oil - position: 10 - dependent_on: has_coal_oil_for_heating_built_environment - slide_key: demand_households_heating_technologies \ No newline at end of file + related_node: households_space_heater_hybrid_airconditioning_combined_network_gas + position: 95 + slide_key: demand_households_heating_technologies diff --git a/config/interface/output_element_series/residential_heating_technologies.yml b/config/interface/output_element_series/residential_heating_technologies.yml index a4669c71d..04d463b65 100644 --- a/config/interface/output_element_series/residential_heating_technologies.yml +++ b/config/interface/output_element_series/residential_heating_technologies.yml @@ -203,6 +203,30 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_before_1945_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 90 + group: residences_before_1945 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_before_1945_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_before_1945_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 95 + group: residences_before_1945 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_before_1945_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_before_1945_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies - label: households_space_heater_coal color: "#333333" @@ -408,6 +432,30 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_1945_1964_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 190 + group: residences_1945_1964 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1945_1964_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1945_1964_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 195 + group: residences_1945_1964 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1945_1964_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1945_1964_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies - label: households_space_heater_coal color: "#333333" @@ -613,6 +661,30 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_1965_1984_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 290 + group: residences_1965_1984 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1965_1984_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1965_1984_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 295 + group: residences_1965_1984 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1965_1984_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1965_1984_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies - label: households_space_heater_coal color: "#333333" @@ -818,6 +890,30 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_1985_2004_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 390 + group: residences_1985_2004 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1985_2004_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1985_2004_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 395 + group: residences_1985_2004 + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_1985_2004_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_1985_2004_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies - label: households_space_heater_coal color: "#333333" @@ -1023,6 +1119,30 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_2005_present_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 490 + group: residences_2005_present + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_2005_present_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_2005_present_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 495 + group: residences_2005_present + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_2005_present_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_2005_present_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies - label: households_space_heater_coal color: "#333333" @@ -1228,3 +1348,27 @@ dependent_on: output_element_key: residential_heating_technologies key: number_of_houses_future_with_space_heater_hybrid_crude_oil_heatpump_air_water_electricity_residential_heating_technologies +- label: households_space_heater_airconditioning_with_heat_pump_boiler + color: "#3EB489" + order_by: 590 + group: residences_future + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_future_with_space_heater_airconditioning_with_heat_pump_boiler + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_future_with_space_heater_airconditioning_with_heat_pump_boiler_residential_heating_technologies +- label: households_space_heater_hybrid_airconditioning_combined_network_gas + color: "#8A9A5B" + order_by: 595 + group: residences_future + show_at_first: + is_target_line: false + target_line_position: + gquery: number_of_houses_future_with_space_heater_hybrid_airconditioning_combined_network_gas + is_1990: + dependent_on: + output_element_key: residential_heating_technologies + key: number_of_houses_future_with_space_heater_hybrid_airconditioning_combined_network_gas_residential_heating_technologies diff --git a/config/locales/interface/input_elements/en_demand_buildings.yml b/config/locales/interface/input_elements/en_demand_buildings.yml index 0f51756ef..ed5f0099f 100644 --- a/config/locales/interface/input_elements/en_demand_buildings.yml +++ b/config/locales/interface/input_elements/en_demand_buildings.yml @@ -376,8 +376,8 @@ en: for space heating.

An air heatpump uses electricity and ambient heat to generate heat. This heat can be transfered to water or air - and used in underfloor heating or airconditioning systems for space heating. - Air heatpumps are similar to airconditioners as they both use ambient air and electricity + and used in underfloor heating or air conditioning systems for space heating. + Air heatpumps are similar to air conditioners as they both use ambient air and electricity to cool the air inside a building. However, older air conditioners are often not equipped with the ability to provide space cooling and heating and operate under lower efficiencies compared to new air heatpumps.

@@ -386,7 +386,7 @@ en: weather curve available in the ETM. The average of these hourly calculations (the Seasonal COP or 'SCOP') can be found in the technical and financial properties.

For more information you can view the - documentation. + documentation. To influence the efficiency of this heatpump you can go to the Costs & efficiencies section or choose to adjust the weather curve. buildings_cooling_heatpump_air_water_electricity_share: @@ -396,11 +396,11 @@ en: for cooling.

An air heatpump uses electricity and ambient cold to generate heat or cold. This cold can be transfered to water or air - and used in underfloor heating or airconditioning systems for cooling.

+ and used in underfloor heating or air conditioning systems for cooling.

Contrary to heating, the efficiency (COP) of this heat pump for cooling is fixed. You can view the efficiency in the technical and financial properties.

For more information you can view the - documentation. + documentation. To influence the efficiency of this heatpump you can go to the Costs & efficiencies section or choose to adjust the weather curve. buildings_space_heater_hybrid_heatpump_air_water_electricity_share: diff --git a/config/locales/interface/input_elements/en_demand_households.yml b/config/locales/interface/input_elements/en_demand_households.yml index 456debc88..cdc93c02e 100644 --- a/config/locales/interface/input_elements/en_demand_households.yml +++ b/config/locales/interface/input_elements/en_demand_households.yml @@ -246,11 +246,11 @@ en: for cooling.

An air heatpump uses electricity and ambient cold to generate cold. This cold can be transfered to water or air - and used in underfloor heating or airconditioning systems for cooling.

+ and used in underfloor heating or air conditioning systems for cooling.

Contrary to heating, the efficiency (COP) of this heat pump for cooling is fixed. You can view the efficiency in the technical and financial properties.

For more information you can view the - documentation. + documentation. To influence the efficiency of this heatpump you can go to the Costs & efficiencies section or choose to adjust the weather curve. households_appliances_electricity_efficiency: @@ -449,13 +449,13 @@ en: for space heating and hot water.

An air heatpump uses electricity and ambient heat to generate heat. This heat can be transfered to water or air - and used in underfloor heating or airconditioning systems for space heating or for the generation of hot water.

+ and used in underfloor heating or air conditioning systems for space heating or for the generation of hot water.

The efficiency (COP) of this heat pump is affected by the outside air temperature and therefore determined by the weather. For every hour a seperate efficiency (COP) is calculated based on the weather curve available in the ETM. The average of these hourly calculations (the Seasonal COP: 'SCOP') can be found in the technical and financial properties.

For more information you can view the - documentation. + documentation. To influence the efficiency of this heatpump you can go to the Costs & efficiencies section or choose to adjust the weather curve. households_heater_heatpump_surface_water_water_ts_electricity_share: @@ -538,7 +538,7 @@ en: to gas. The threshold value can be adjusted in the section Demand response - behavior of hybrid heat pumps.

- More information on how hybrid heat pumps work can be found in the documentation + More information on how hybrid heat pumps work can be found in the documentation households_heater_hybrid_hydrogen_heatpump_air_water_electricity_share: title: Hybrid air heat pump (hydrogen) short_description: @@ -552,7 +552,7 @@ en: The threshold value can be adjusted in the section Demand response - behavior of hybrid heat pumps.

- More information on how hybrid heat pumps work can be found in the documentation + More information on how hybrid heat pumps work can be found in the documentation households_heater_hybrid_crude_oil_heatpump_air_water_electricity_share: title: Hybrid air heat pump (oil) short_description: @@ -572,7 +572,32 @@ en: The threshold value can be adjusted in the section Demand response - behavior of hybrid heat pumps.

- More information on how hybrid heat pumps work can be found in the documentation + More information on how hybrid heat pumps work can be found in the documentation + households_heater_hybrid_airconditioning_combined_network_gas_share: + title: Air conditioning with combi boiler (gas) + short_description: '' + description: | + This heating option is a combination of an air conditioning unit that + can also heat (an air-to-air heat pump) with a gas-fired combi boiler + for space heating and hot water. +

+ The air conditioning unit supplies as much of the space heating demand + as its capacity allows. The combi boiler meets the remaining space + heating demand and also provides all hot water. + More information on how this system works can be found in the heat pump documentation. +

+ The capacity of the air conditioning unit can be adjusted in the section + Capacities. + households_heater_airconditioning_with_heat_pump_boiler_share: + title: Air conditioning with heat pump boiler + short_description: '' + description: | + This heating option is a combination of an air conditioning unit that + can also heat (an air-to-air heat pump) for space heating with a + separate heat pump boiler for hot water production. +

+ The capacity of the air conditioning unit can be adjusted in the section + Capacities. households_cooker_network_gas_share: title: Gas short_description: @@ -638,72 +663,174 @@ en: description: '' households_heater_coal_heat_output_capacity: title: Coal heater - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of a coal heater for space heating. The same capacity is assumed to be + available for hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_crude_oil_heat_output_capacity: title: Oil heater - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of an oil heater for space heating. The same capacity is assumed to be + available for hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_network_gas_heat_output_capacity: title: Gas-fired heater - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of a gas-fired heater for space heating. The same capacity is assumed to be + available for hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_combined_network_gas_heat_output_capacity: title: Condensing combi boiler (gas) - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one condensing combi boiler (gas), used for both space heating and + hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_combined_hydrogen_heat_output_capacity: title: Condensing combi boiler (hydrogen) - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one condensing combi boiler (hydrogen), used for both space + heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_wood_pellets_heat_output_capacity: title: Wood pellet boiler - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of a wood pellet boiler for space heating. The same capacity is assumed to be + available for hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_electricity_heat_output_capacity: title: Electric boiler - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of an electric boiler for space heating. The same capacity is assumed to be + available for hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_heatpump_air_water_electricity_heat_output_capacity: title: Air heat pump - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one air heat pump, used for both space heating and hot water. The + electrical capacity of the heat pump scales proportionally.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_heatpump_ground_water_electricity_heat_output_capacity: title: Ground heat pump - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one ground heat pump, used for both space heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_heatpump_surface_water_water_ts_electricity_heat_output_capacity: title: Aquathermal heat pump with TS (surface water) - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one aquathermal heat pump with thermal storage (TS), used for both + space heating and hot water. The electrical capacity of the heat pump scales proportionally.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_heatpump_pvt_electricity_heat_output_capacity: title: Ground heat pump with PVT - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one ground heat pump with photovoltaic-thermal (PVT) panels, used + for both space heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_district_heating_lt_steam_hot_water_heat_output_capacity: title: LT district heating - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one low temperature (LT) district heating connection, used for + both space heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_district_heating_mt_steam_hot_water_heat_output_capacity: title: MT district heating - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one medium temperature (MT) district heating connection, used for + both space heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_district_heating_ht_steam_hot_water_heat_output_capacity: title: HT district heating - short_description: '' - description: '' + short_description: + description: | + Total thermal capacity of one high temperature (HT) district heating connection, used for + both space heating and hot water.

+ If the capacity is too low, heat demand in some hours is not met. See the documentation for more information. households_heater_hybrid_heatpump_air_water_electricity_heat_output_capacity: title: Hybrid air heat pump (gas) - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of the heat pump in one hybrid air heat pump (gas) for space heating. The + capacity of the gas boiler, and with it the hot water capacity, scales proportionally with + this slider.

+ See the documentation for more information. households_heater_hybrid_hydrogen_heatpump_air_water_electricity_heat_output_capacity: title: Hybrid air heat pump (hydrogen) - short_description: '' - description: '' + short_description: + description: | + Thermal capacity of the heat pump in one hybrid air heat pump (hydrogen) for space heating. + The capacity of the hydrogen boiler, and with it the hot water capacity, scales + proportionally with this slider.

+ See the documentation for more information. households_heater_hybrid_crude_oil_heatpump_air_water_electricity_heat_output_capacity: - title: Hybrid air heat pump (crude oil) - short_description: '' - description: '' + title: Hybrid air heat pump (oil) + short_description: + description: | + Thermal capacity of the heat pump in one hybrid air heat pump (oil) for space heating. + The capacity of the oil boiler does not change with this slider.

+ See the documentation for more information. + households_heater_airconditioning_with_heat_pump_boiler_heat_output_capacity: + title: Air conditioning with heat pump boiler + short_description: + description: | + Thermal capacity of one air conditioning unit for space heating. A separate heat pump boiler + supplies hot water. Its capacity scales proportionally with this slider.

+ See the documentation for more information. + households_heater_hybrid_airconditioning_combined_network_gas_heat_output_capacity: + title: Air conditioning with combi boiler (gas) + short_description: + description: | + Thermal capacity of one air conditioning unit combined with a condensing combi boiler (gas), + for space heating. The capacity of the combi boiler, and with it the hot water capacity, + scales proportionally with this slider.

+ See the documentation for more information. households_diesel_in_crude_oil_share: title: Diesel short_description: diff --git a/config/locales/interface/input_elements/en_flexibility.yml b/config/locales/interface/input_elements/en_flexibility.yml index fa17d3190..2dded7c0b 100644 --- a/config/locales/interface/input_elements/en_flexibility.yml +++ b/config/locales/interface/input_elements/en_flexibility.yml @@ -426,7 +426,7 @@ en: price financial optimization for the user is achieved with a threshold COP of 2.6, this can be concluded from the chart on the right.

For more information - about (hybrid) heat pumps see our documentation. + about (hybrid) heat pumps see our documentation. flexibility_heat_pump_space_heating_cop_cutoff_crude_oil: title: Space heating (oil) short_description: @@ -437,7 +437,7 @@ en: is used maximally for space heating. With the current oil and electricity price financial optimization for the user is achieved with a threshold COP of 3.7.

- For more information about (hybrid) heat pumps see our documentation. + For more information about (hybrid) heat pumps see our documentation. flexibility_heat_pump_water_heating_cop_cutoff: title: Hot water short_description: @@ -445,7 +445,7 @@ en: Here you indicate the threshold COP of hybrid heat pumps for hot water.

The default setting is that the fuel-fired part of the HHP (using network gas, hydrogen or oil) is used for hot water. The threshold COP is therefore set at its maximum value of 6.0 so that the fuel-fired part is always enabled.

- For calculations on the threshold COP see documentation + For calculations on the threshold COP see documentation households_flexibility_consumer_gas_price: title: Gas price short_description: diff --git a/config/locales/interface/input_elements/nl_demand_buildings.yml b/config/locales/interface/input_elements/nl_demand_buildings.yml index df44513cf..c9e696d76 100644 --- a/config/locales/interface/input_elements/nl_demand_buildings.yml +++ b/config/locales/interface/input_elements/nl_demand_buildings.yml @@ -389,7 +389,7 @@ nl: uurlijkse berekeningen (de seizoensafhankelijke COP: 'SCOP') kan worden gevonden in de technische parameters en kosten.

Ga voor meer informatie naar de - documentatie. + documentatie. Om de efficientie (COP) te beïnvloeden kun je naar de Kosten & efficiënties gaan of het weerjaar aanpassen. @@ -404,7 +404,7 @@ nl: De efficiëntie (COP) van de luchtwarmtepomp voor koeling (in tegenstelling tot verwarming) is vastgesteld. Deze kun je vinden in de technische parameters en kosten.

Ga voor meer informatie naar de - documentatie. + documentatie. Om de efficientie (COP) te beïnvloeden kun je naar de Kosten & efficiënties gaan of het weerjaar aanpassen. diff --git a/config/locales/interface/input_elements/nl_demand_households.yml b/config/locales/interface/input_elements/nl_demand_households.yml index b4e7d56be..577f9f2b3 100644 --- a/config/locales/interface/input_elements/nl_demand_households.yml +++ b/config/locales/interface/input_elements/nl_demand_households.yml @@ -253,7 +253,7 @@ nl: De efficiëntie (COP) van de luchtwarmtepomp voor koeling (in tegenstelling tot verwarming) is vastgesteld. Deze kun je vinden in de technische parameters en kosten.

Ga voor meer informatie naar de - documentatie. + documentatie. Om de efficientie (COP) te beïnvloeden kun je naar de Kosten & efficiënties gaan of het weerjaar aanpassen. @@ -482,7 +482,7 @@ nl: uurlijkse berekeningen (de seizoensafhankelijke COP: 'SCOP') kan worden gevonden in de technische parameters en kosten.

Ga voor meer informatie naar de - documentatie. + documentatie. Om de efficientie (COP) te beïnvloeden kun je naar de Kosten & efficiënties gaan of het weerjaar aanpassen. @@ -566,7 +566,7 @@ nl: over op gas. De omslag-COP is in de sectie Vraagsturing - gedrag van hybride warmtepompen aan te passen.

- Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie + Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie households_heater_hybrid_hydrogen_heatpump_air_water_electricity_share: title: Hybride luchtwarmtepomp (waterstof) short_description: @@ -579,7 +579,7 @@ nl: Deze omslag-COP is in de sectie Vraagsturing - gedrag van hybride warmtepompen aan te passen.

- Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie + Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie households_heater_hybrid_crude_oil_heatpump_air_water_electricity_share: title: Hybride luchtwarmtepomp (olie) short_description: @@ -597,7 +597,32 @@ nl: Deze omslag-COP is in de sectie Vraagsturing - gedrag van hybride warmtepompen aan te passen.

- Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie + Meer informatie over hoe hybride warmtepompen werken is te vinden in de documentatie + households_heater_hybrid_airconditioning_combined_network_gas_share: + title: Airco met HR combiketel (gas) + short_description: '' + description: | + Deze verwarmingsoptie is een combinatie van een airconditioner die ook kan + verwarmen (een lucht-luchtwarmtepomp) met een gasgestookte HR-combiketel + voor ruimteverwarming en warm tapwater. +

+ De airco levert zoveel van ruimteverwarmingsvraag als zijn vermogen + toelaat. De HR-combiketel vult de resterende vraag naar ruimteverwarming in + en levert daarnaast al het warm tapwater. + Meer informatie over hoe dit systeem werkt is te vinden in de documentatie over warmtepompen. +

+ Het vermogen van de airco is in de sectie + Vermogens aan te passen. + households_heater_airconditioning_with_heat_pump_boiler_share: + title: Airco met warmtepompboiler + short_description: '' + description: | + Deze verwarmingsoptie is een combinatie van een airconditioner die ook kan + verwarmen (een lucht-luchtwarmtepomp) voor ruimteverwarming met een aparte + warmtepompboiler voor de productie van warm tapwater. +

+ Het vermogen van de airco is in de sectie + Vermogens aan te passen. households_cooker_network_gas_share: title: Gas short_description: '' @@ -659,72 +684,176 @@ nl: description: '' households_heater_coal_heat_output_capacity: title: Kolenketel - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van een kolenketel voor ruimteverwarming. Voor warm water wordt + aangenomen dat dezelfde capaciteit beschikbaar is.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_crude_oil_heat_output_capacity: title: Olieketel - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van een olieketel voor ruimteverwarming. Voor warm water wordt + aangenomen dat dezelfde capaciteit beschikbaar is.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_network_gas_heat_output_capacity: title: Gasketel - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van een gasketel voor ruimteverwarming. Voor warm water wordt dezelfde + aangenomen dat capaciteit aangenomen beschikbaar is.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_combined_network_gas_heat_output_capacity: title: HR combiketel (gas) - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één HR-combiketel (gas), gebruikt voor zowel + ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_combined_hydrogen_heat_output_capacity: title: HR combiketel (waterstof) - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één HR-combiketel (waterstof), gebruikt voor zowel + ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_wood_pellets_heat_output_capacity: title: Houtpelletkachel - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van een houtpelletkachel voor ruimteverwarming. Voor warm water wordt + aangenomen dat dezelfde capaciteit beschikbaar is.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_electricity_heat_output_capacity: title: Elektrische boiler/bijstook - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van een elektrische boiler voor ruimteverwarming. Voor warm water wordt + aangenomen dat dezelfde capaciteit beschikbaar is.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_heatpump_air_water_electricity_heat_output_capacity: title: Luchtwarmtepomp - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één luchtwarmtepomp, gebruikt voor zowel ruimteverwarming + als warm water. De elektrische capaciteit van de warmtepomp schaalt naar verhouding mee.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_heatpump_ground_water_electricity_heat_output_capacity: title: Bodemwarmtepomp - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één bodemwarmtepomp, gebruikt voor zowel ruimteverwarming + als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_heatpump_surface_water_water_ts_electricity_heat_output_capacity: title: Warmtepomp met aquathermie (TEO) en WKO - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één warmtepomp met aquathermie (thermische energie uit + oppervlaktewater, TEO) en warmte-koudeopslag (WKO), gebruikt voor zowel ruimteverwarming als + warm water. De elektrische capaciteit van de warmtepomp schaalt naar verhouding mee.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_heatpump_pvt_electricity_heat_output_capacity: title: Bodemwarmtepomp met PVT - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één bodemwarmtepomp met PVT-panelen + (photovoltaïsch-thermisch), gebruikt voor zowel ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_district_heating_lt_steam_hot_water_heat_output_capacity: title: LT-warmtenet - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één aansluiting op een lagetemperatuur (LT) warmtenet, + gebruikt voor zowel ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_district_heating_mt_steam_hot_water_heat_output_capacity: title: MT-warmtenet - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één aansluiting op een middentemperatuur (MT) warmtenet, + gebruikt voor zowel ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_district_heating_ht_steam_hot_water_heat_output_capacity: title: HT-warmtenet - short_description: '' - description: '' + short_description: + description: | + Totale thermische capaciteit van één aansluiting op een hogetemperatuur (HT) warmtenet, + gebruikt voor zowel ruimteverwarming als warm water.

+ Als de capaciteit te laag is, wordt de warmtevraag in sommige uren niet gedekt. Zie de documentatie voor meer informatie. households_heater_hybrid_heatpump_air_water_electricity_heat_output_capacity: title: Hybride luchtwarmtepomp (gas) - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van de warmtepomp in één hybride luchtwarmtepomp (gas) voor + ruimteverwarming. De capaciteit van de gasketel, en daarmee de capaciteit voor warm water, + schaalt naar verhouding mee met deze schuif.

+ Zie de documentatie voor meer informatie. households_heater_hybrid_hydrogen_heatpump_air_water_electricity_heat_output_capacity: title: Hybride luchtwarmtepomp (waterstof) - short_description: '' - description: '' + short_description: + description: | + Thermische capaciteit van de warmtepomp in één hybride luchtwarmtepomp (waterstof) voor + ruimteverwarming. De capaciteit van de waterstofketel, en daarmee de capaciteit voor warm + water, schaalt naar verhouding mee met deze schuif.

+ Zie de documentatie voor meer informatie. households_heater_hybrid_crude_oil_heatpump_air_water_electricity_heat_output_capacity: - title: Hybride luchtwarmtepomp (ruwe olie) - short_description: '' - description: '' + title: Hybride luchtwarmtepomp (olie) + short_description: + description: | + Thermische capaciteit van de warmtepomp in één hybride luchtwarmtepomp (olie) voor + ruimteverwarming. De capaciteit van de olieketel verandert niet mee met deze schuif.

+ Zie de documentatie voor meer informatie. + households_heater_airconditioning_with_heat_pump_boiler_heat_output_capacity: + title: Airco met warmtepompboiler + short_description: + description: | + Thermische capaciteit van één airco voor ruimteverwarming. Een aparte warmtepompboiler + levert het warme water. De capaciteit hiervan schaalt naar verhouding mee met deze schuif.

+ Zie de documentatie voor meer informatie. + households_heater_hybrid_airconditioning_combined_network_gas_heat_output_capacity: + title: Airco met HR combiketel (gas) + short_description: + description: | + Thermische capaciteit van één airco in combinatie met een HR-combiketel (gas), voor + ruimteverwarming. De capaciteit van de combiketel, en daarmee de capaciteit voor warm water, + schaalt naar verhouding mee met deze schuif.

+ Zie de documentatie voor meer informatie. households_diesel_in_crude_oil_share: title: Diesel short_description: diff --git a/config/locales/interface/input_elements/nl_flexibility.yml b/config/locales/interface/input_elements/nl_flexibility.yml index f8ee52f89..c62a5906f 100644 --- a/config/locales/interface/input_elements/nl_flexibility.yml +++ b/config/locales/interface/input_elements/nl_flexibility.yml @@ -434,7 +434,7 @@ nl: ruimteverwarming. Met de huidige gas- en elektriciteitsprijs wordt financiële optimalisatie voor de gebruiker bereikt met een omslag-COP van 2.6. Dit is te zien in de grafiek rechts. Voor meer informatie over (hybride) - warmtepompen zie onze documentatie. + warmtepompen zie onze documentatie. flexibility_heat_pump_space_heating_cop_cutoff_crude_oil: title: Ruimteverwarming (olie) short_description: @@ -446,7 +446,7 @@ nl: optimalisatie voor de gebruiker bereikt met een omslag-COP van 3.7.

Voor meer informatie over (hybride) - warmtepompen zie onze documentatie. + warmtepompen zie onze documentatie. flexibility_heat_pump_water_heating_cop_cutoff: title: Warm water short_description: @@ -455,7 +455,7 @@ nl: voor warm water.

Met de standaardinstelling voor de omslag-COP wordt het brandstofdeel van de hybride warmtepomp (op netwerkgas, waterstof of olie) maximaal gebruikt voor verwarmen van tapwater. De omslag-COP staat daarom ingesteld op de maximale waarde van 6,0, zodat het brandstofdeel altijd ingeschakeld is voor tapwater.

- Voor meer informatie zie: documentatie. + Voor meer informatie zie: documentatie. households_flexibility_consumer_gas_price: title: Gasprijs short_description: diff --git a/config/locales/interface/output_element_series/en_labels.yml b/config/locales/interface/output_element_series/en_labels.yml index a2ebe0781..61699d390 100644 --- a/config/locales/interface/output_element_series/en_labels.yml +++ b/config/locales/interface/output_element_series/en_labels.yml @@ -856,9 +856,11 @@ en: households_space_heater_hybrid_heatpump_air_water_electricity: "Hybrid air heat pump (gas)" households_space_heater_hybrid_hydrogen_heatpump_air_water_electricity: "Hybrid air heat pump (hydrogen)" households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity: "Hybrid air heat pump (crude oil)" + households_space_heater_airconditioning_with_heat_pump_boiler: "Air conditioning with heat pump boiler" + households_space_heater_hybrid_airconditioning_combined_network_gas: "Air conditioning with combi boiler (gas)" households_space_heater_network_gas: "Gas-fired heater" households_space_heater_wood_pellets: "Wood pellet boiler" - households_space_heater_hybrid_heatpump_electricity_input_curve: "Elektricity" + households_space_heater_hybrid_heatpump_electricity_input_curve: "Electricity" households_space_heater_hybrid_heatpump_network_gas_input_curve: "Network gas" households_water_heater_coal: "Coal-fired heater water heating" households_water_heater_combined_network_gas: "Condensing combi boiler water heating" diff --git a/config/locales/interface/output_element_series/nl_labels.yml b/config/locales/interface/output_element_series/nl_labels.yml index f41e9d6c7..791167ec1 100644 --- a/config/locales/interface/output_element_series/nl_labels.yml +++ b/config/locales/interface/output_element_series/nl_labels.yml @@ -218,7 +218,7 @@ nl: ammonia_non_energetic: "Ammoniak (grondstof)" ammonia: "Ammoniak" ammonia_heating: "Ammoniak (voor verwarming)" - ammonnia_hot_water: "Ammoniak (voor warm water)" + ammonia_hot_water: "Ammoniak (voor warm water)" ammonia_ships: "Ammoniakschepen" electricity_ships: "Elektrische schepen" hydrogen_ships: "Waterstofschepen" @@ -868,6 +868,8 @@ nl: households_space_heater_hybrid_heatpump_air_water_electricity: "Hybride luchtwarmtepomp (gas)" households_space_heater_hybrid_hydrogen_heatpump_air_water_electricity: "Hybride luchtwarmtepomp (waterstof)" households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity: "Hybride luchtwarmtepomp (olie)" + households_space_heater_airconditioning_with_heat_pump_boiler: "Airco met warmtepompboiler" + households_space_heater_hybrid_airconditioning_combined_network_gas: "Airco met combiketel (gas)" households_space_heater_network_gas: "Gasketel" households_space_heater_wood_pellets: "Houtpelletkachel" households_space_heater_hybrid_heatpump_electricity_input_curve: "Elektriciteit" diff --git a/config/locales/interface/output_elements/labels_groups/en_labels.yml b/config/locales/interface/output_elements/labels_groups/en_labels.yml index cf2c8611c..b9cedd385 100644 --- a/config/locales/interface/output_elements/labels_groups/en_labels.yml +++ b/config/locales/interface/output_elements/labels_groups/en_labels.yml @@ -135,6 +135,8 @@ en: households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity: "Hybrid air heat pump (oil)" households_space_heater_network_gas: "Gas-fired heater" households_space_heater_wood_pellets: "Wood pellet boiler" + households_space_heater_airconditioning_with_heat_pump_boiler: "Air conditioning with heat pump boiler" + households_space_heater_hybrid_airconditioning_combined_network_gas: "Air conditioning with combi boiler (gas)" hydrogen_supply_order: energy_hydrogen_storage_salt_cavern: "Salt cavern hydrogen storage" energy_hydrogen_storage_depleted_gas_field: "Depleted gas field hydrogen storage" diff --git a/config/locales/interface/output_elements/labels_groups/nl_labels.yml b/config/locales/interface/output_elements/labels_groups/nl_labels.yml index 129b49244..317691c87 100644 --- a/config/locales/interface/output_elements/labels_groups/nl_labels.yml +++ b/config/locales/interface/output_elements/labels_groups/nl_labels.yml @@ -133,6 +133,8 @@ nl: households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity: "Hybride luchtwarmtepomp (ruwe olie)" households_space_heater_network_gas: "Gasketel" households_space_heater_wood_pellets: "Houtpelletkachel" + households_space_heater_airconditioning_with_heat_pump_boiler: "Airco met warmtepompboiler" + households_space_heater_hybrid_airconditioning_combined_network_gas: "Airco met HR combiketel (gas)" hydrogen_supply_order: energy_hydrogen_storage_salt_cavern: "Waterstof uit opslag zoutcaverne" energy_hydrogen_storage_depleted_gas_field: "Waterstof uit opslag leeg gasveld" diff --git a/config/locales/interface/slides/en_flexibility.yml b/config/locales/interface/slides/en_flexibility.yml index 827f260a5..6a51970d5 100644 --- a/config/locales/interface/slides/en_flexibility.yml +++ b/config/locales/interface/slides/en_flexibility.yml @@ -113,7 +113,7 @@ en: threshold then the HHP switches from electricity to a backup fuel. This can be network gas, hydrogen or oil. You can choose a setting that is most financially attractive for the consumer, but you can also choose a setting that produces less impact on the electricity network. - See the documentation + See the documentation for more information on the threshold COP.

Specifically for gas HHPs the chart diff --git a/config/locales/interface/slides/nl_flexibility.yml b/config/locales/interface/slides/nl_flexibility.yml index 09f89c58e..18f161cff 100644 --- a/config/locales/interface/slides/nl_flexibility.yml +++ b/config/locales/interface/slides/nl_flexibility.yml @@ -118,6 +118,8 @@ nl: Je kan deze instellen op de financieel meest aantrekkelijke voor de consument, maar kan ook een instelling kiezen die minder netwerkimpact oplevert. + Zie de documentatie + voor meer informatie over de omslag-COP.

Specifiek voor gasgestookte hybride warmtepompen helpt de grafiek diff --git a/config/nodes_download_source.yml b/config/nodes_download_source.yml index 337cb4af0..6d3cac93b 100644 --- a/config/nodes_download_source.yml +++ b/config/nodes_download_source.yml @@ -121,6 +121,8 @@ households_space_heater_network_gas: https://github.com/quintel/etdataset-public households_space_heater_hybrid_heatpump_air_water_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/households/households_space_heater_hybrid_heatpump_air_water_electricity.xlsx?raw=true households_space_heater_hybrid_hydrogen_heatpump_air_water_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/households/households_space_heater_hybrid_hydrogen_heatpump_air_water_electricity.converter.xlsx?raw=true households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/households/households_space_heater_hybrid_crude_oil_heatpump_air_water_electricity.xlsx?raw=true +households_space_heater_airconditioning_with_heat_pump_boiler: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/households/households_space_heater_airconditioning_with_heat_pump_boiler.xlsx?raw=true +households_space_heater_hybrid_airconditioning_combined_network_gas: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/households/households_space_heater_hybrid_airconditioning_combined_network_gas.xlsx?raw=true transport_car_flexibility_p2p_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/transport/transport_car_flexibility_p2p_electricity.converter.xlsx?raw=true energy_flexibility_pumped_storage_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/energy/energy_flexibility_pumped_storage_electricity.xlsx?raw=true energy_flexibility_hv_opac_electricity: https://github.com/quintel/etdataset-public/blob/master/nodes_source_analyses/energy/energy/energy_flexibility_hv_opac_electricity.xlsx?raw=true